A. Power capping helps mainly in reducing data center footprint.
B. Power capping helps reduce data center cooling.
C. A single power cap group policy allows you to set power limits across multiple UCS domains.
D. You can have multiple power cap groups per UCS domain.
E. Each blade within a UCS 5108 chassis can belong to a separate power cap group.
您可能感興趣的試卷
你可能感興趣的試題
A. from 10:00:00:00:00:00:00:00 to 10:FF:FF:FF:FF:FF:FF:FF
B. from 20:00:00:00:00:00:00:00 to 20:FF:FF:FF:FF:FF:FF:FF
C. from 30:00:00:00:00:00:00:00 to 30:FF:FF:FF:FF:FF:FF:FF
D. from 40:00:00:00:00:00:00:00 to 40:FF:FF:FF:FF:FF:FF:FF
A. NPIV provides a means to assign multiple Fibre Channel IDs to a single N-port.
B. NPIV can be enabled on a per-VSAN basis.
C. NPIV requires a "write erase" and then reload the switch in order to come up into NPIV mode.
D. NPIV is a Cisco proprietary feature and as such works only between two Cisco switches.
E. NPIV must not be enabled on a switch that is also running N-port virtualization.
A. 2
B. 3
C. 4
D. 6
E. 12
A. After enabling NPIV, switch interfaces can only be placed into NP, F, or SD modes of operation.
B. NPV devices log in to NPIV devices.
C. NPIV requires the Enterprise License Package.
D. NPIV is supported on the Cisco MDS, N7K, and N5K families of switches.
E. A director class switch should not be placed into NPIV mode.
A. B200
B. C210
C. B250
D. C260
E. C460
A. 800 MHz
B. 900 MHz
C. 1066 MHz
D. 1333 MHz
E. 1666 MHz
A. Dual-rank DIMMs are not supported.
B. 16-GB DIMMs are too slow.
C. The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GB
D. The memory bus would be too long.
E. The blade would run too hot.
A. Missing control VLAN in VSM configuration
B. Missing packet VLAN in VSM configuration
C. VSM has no network connection to vCenter
D. VSM extension key is not installed on vCenter
E. vCenter extension key is not installed on VSM
The network administrator is adding a new N1Kv to the vCenter, however, the administrator does not see the new switch under the networking tab of vCenter.
The administrator issues the following command on the VSM to troubleshoot:
VSM# show svs connections
connection VC:
ip address: 10.10.10.30
remote port: 80
protocol: vmware-vim https
certificatE. default
datacenter namE. DC1
DVS uuiD. 67 32 30 50 a6 d2 49 64-9e 1c 5f 49 e3 af 55 99
config status: Disabled
operational status: Disconnected sync status: -
version: -
When attempting to fix the issue, the following error is seen:
VSM-PRI-188# conf
VSM-PRI-188(config)# svs connection VC
VSM-PRI-188(config-svs-conn)# connect
ERROR: [VMWARE-VIM] Extension key was not registered before its use
What is the cause of the error?()
A. Missing control VLAN in VSM configuration
B. Missing packet VLAN in VSM configuration
C. VSM has no network connection to vCenter
D. VSM extension key is not installed on vCenter
E. vCenter extension key is not installed on VSM
Given the following configuration:
port-profile type ethernet DATA-UPLINK
vmware port-group
switchport trunk allowed vlan 1-3967,4048-4093
channel-group auto mode on
no shutdown
state enabled
port-profile type ethernet MGMT-UPLINK
vmware port-group
switchport trunk allowed vlan 10-12
channel-group auto mode on
no shutdown
state enabled
VEMs are seen to be joining and then are lost from the Cisco VSM. How would you resolve this issue?()
A. Remove second NIC from each port profile
B. Remove VEM from VSM (no vem X), remove NICs, and reinsert
C. Ensure that VLANs on uplink profiles are not overlapping
D. Reinstall VEM
E. Issue the command "module vem X execute vemcmd set pinning module vsm 1"
最新試題
Which statements are true regarding the Cisco UCS fabric failover feature? ()
What is the appliance port used to connect to in a Cisco Unified Computing System?()
When testing ICMP access to a functional load-balancing ACE VIP, it fails. What is the reason of this problem? ()
What would be the cause for the following fault in UCS Manager?() "ether VIF x / xxx down, reason: ENM source pinning failed"
What is the use of an "all configuration" backup in Cisco UCS?()
On a Cisco Unified Computing System (UCS), which two statements regarding Ethanalyzer are true?()
Your company wants Server 1/eth0 (vNIC 1) configured so that it always uses Fabric Interconnect A Port Channel 1 (Po1) when it communicates with anything outside of the Cisco UCS domain. However, if vNIC 1 fails over to Fabric Interconnect B using fabric failover, then vNIC 1 can any uplink port on Fabric Interconnect B. Which statements are true? ()
What is the purpose of this command in a Cisco Application Control Engine?() switch/Admin# show np 1 me-stats "-F0 v"
An administrator is creating a service profile but receives an error when applying to a blade. The administrator checks the faults tab of the service profile and finds the following error (Refer to the exhibit).What is the cause of this error?()
What interface is created when an FC Port Channel is created on a Cisco Unified Computing System?()