n1kv-l3(config)# show lacp offload status
Current Status : Enabled
Running Config Status : Enabled
Saved Config Status : Disabled
What two facts does the output signify? ()
A. LACP is enabled on the Nexus 1000v.
B. LACP will be offloaded to the upstream switch.
C. LACP will be negotiated to the VM.
D. LACP is negotiated by the VSM.
E. LACP is negotiated by the VEM in all instances.
您可能感興趣的試卷
你可能感興趣的試題
A. intelligent traffic steering to the VSG
B. offloading the processing from the VSG to the VEM
C. intelligent traffic steering to the VNMC
D. offloading the processing from the VSG to the flow manager
E. deep packet inspection
A. channel-group auto mode on
B. channel-group auto mode active
C. channel-group auto mode on sub-group cdp
D. channel-group auto mode on sub-group manual
E. channel-group auto mode on mac-pinning
A. accounting
B. authentication
C. authorization
D. network monitoring
E. network planning
A. 0
B. 1
C. 2
D. 3
E. 4
F. 5
When configuring vPC-HM CDP with multiple links to the same switch, are port-channels required?()
A. Each link between the upstream switch and the VEM is an individual subgroup.
B. Connections that go to the same upstream switch must be configured with the command channel-group
C. Connections that go to the same upstream switch must be configured with the command channel-group
D. With vPC-HM CDP, the user can pin traffic from a specific VM to a specific uplink.
E. Connections that go to the same upstream switch must be configured with the command channel-group
A. 0
B. 1
C. 2
D. 3
E. 4
A. use summary view in the device manager
B. from the DCNM-SAN client, view ISLs in real time from the Performance drop-down list
C. for each port channel, select Monitor Continually
D. configure traps for each port channel to utilize RMON
E. set up flows with the DCNM-SAN client and use the Performance Manager web client for performance collections
A Host connected to an NPV switch is not able to see the storage connected to the core switch. Given the output of the show command below, what is the reason of this issue?()
switch# show npv status
npiv is enabled
External Interfaces:
===============
InterfacE. fc1/1, VSAN: 1, FCID. 0x000000, StatE. Other
Number of External Interfaces: 4
A. NPV is not enabled on the core switch?
B. The interface connected to the Core switch is in admin down state
C. The local host interface belongs to the wrong VSAN?
D. The local host interface is not able to login
A. The switch receives the FCoE frame and forwards it to another switch over its VE port.
B. The switch receives the FCoE frame, deapsulates it, and sends the Fibre Channel frame to the fabric over its Fibre Channel uplink port.
C. The switch receives the FCoE frame, deapsulates it, and sends the Fibre Channel frame to the Fibre Channel target over its Fibre Channel port.
D. The switch receives the FCoE frame and forwards it to another FCoE device over its VN port.
A. Up to 25 m bus length
B. Only one device per SCSI bus
C. Up to 16 devices per SCSI bus
D. Half-duplex operation
E. Full-duplex operation
最新試題
What is the purpose of this command in a Cisco Application Control Engine?() switch/Admin# show np 1 me-stats "-F0 v"
Refer to the exhibit.The Cisco UCS domain is operating in switching mode. A network administrator notices that no traffic is traversing the uplinks on Fabric Interconnect B (Path C). Which actions might be used to change this behavior?()
Which statement is true about "full state backup" in a Cisco Unified Computing System?()
What is the use of an "all configuration" backup in Cisco UCS?()
Which three statements are possible causes for the "fltAdaptorHostIfLink-down" fault in UCS Manager? ()
A Cisco UCS fabric interconnect in end-host mode learns MAC addresses on which port types?()
An administrator creates a vNIC and assigns it to Fabric A with the fabric failover feature enabled. Which statement is true?()
Refer to the exhibit. According to the equipment tab in Cisco UCS Manager, which is true?()
What would be the cause for the following fault in UCS Manager?() "ether VIF x / xxx down, reason: ENM source pinning failed"
What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()